ESP convertion into fabric filter

Technical solution with multiple compartments in the clean gas side only. Suitable to close one of six compartments in case of dust emission problem

Figure 1 top view of  Fabric Filter in WAH plant, Pakistan

Basic design data

FILTER DESIGN CAPACITY Am3/h 538.900
TOTAL FILTERING SURFACE AREA m2 8.848
BAG SIZE mm ø152 x 10,000
COMPRESSED AIR CONSUMPTION (2,5 BAR) Nm3/h 82
NUMBER OF BAGS PER ROW No. 22
DUST CONCENTRATION AT INLET g/Nm3 100

Scope: ESP convertion into fabric filter
Country: Pakistan
Application: Kiln& Raw mill – 3500TPD
Brownfield engineering: existing equipment fully reused to keep low the total cost of ownership.
All technological equipments certified EU origin.
Cleaning System: SWAP cleaning system