New Fabric Filter & Gas Cooling
Different technology & application: combined APC system with gas cooling on clinker cooler, integrated with APC system on raw mill.

Process Filter
Raw Mill

Process Filter
Clinker Cooler

Heat Exchanger
Clinker Cooler
Greenfield engineering
Cleaning System for filter: SWAP Technology
Start-up: March 2015
Filter design data: Raw Mill
FILTER DESIGN CAPACITY | Am3/h | 560,000 |
BAG SIZE | mm | ø152 x 10,000 |
NUMBER OF BAGS PER ROW | No. | 21 |

Filter design data: Clinker
FILTER DESIGN CAPACITY | Am3/h | 610,000 |
BAG SIZE | mm | ø152 x 9,000 |
NUMBER OF BAGS PER ROW | No. | 20 |

HE design data: Clinker
HE DESIGN CAPACITY | Am3/h | 876,000 |
EXCHANGE AREA | m2 | 8,258 |
TEMPERATURE IN/OUT | °C | 400 / 180 |